Genie GTH-1056 Service And Repair Manual page 25

From gth1016e-11305 to gth1016e-11799 includes gth1016e-11281 gth1016e-11282 gth1016e-11286 from gth10e-11800
Hide thumbs Also See for GTH-1056:
Table of Contents

Advertisement

April 2017
3
Working clockwise on the body hex fitting,
make a second mark with a permanent ink
marker to indicate the proper tightening
position. Refer to Illustration 2.
Note: Use the JIC 37° Fitting table in this section to
determine the correct number of flats, for the proper
tightening position.
Note: The marks indicate the correct tightening
positions have been determined. Use the second
mark on the body hex fitting to properly tighten the
joint after it has been loosened.
Illustration 2
1 body hex fitting
2 reference mark
3 second mark
4
Tighten the hex nut until the mark on the hex
nut is aligned with the second mark on the
body hex fitting.
5
Operate all machine functions and inspect the
hose, fittings and related components to
confirm there are no leaks.
Part No. 1278145
GTH-1056
Service and Repair Manual
Specifications