Genie GTH-1056 Service And Repair Manual page 114

From gth1016e-11305 to gth1016e-11799 includes gth1016e-11281 gth1016e-11282 gth1016e-11286 from gth10e-11800
Hide thumbs Also See for GTH-1056:
Table of Contents

Advertisement

Service and Repair Manual
Deutz TCD3.6 Engine Fault Codes
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
24116 65364 9
Timeout error of CAN-Transmit-Frame SCR2
24117 65365 9
Timeout error of CAN-Transmit-Frame SCR3
24118 65366 9
Timeout error of CAN-Receive-Frame ComRxCM0
24119 65367 9
Timeout error of CAN-Receive-Frame ComRxCustSCR2
24120 65368 9
Timeout error of CAN-Receive-Frame ComRxSCRHtDiag
24121 65369 9
Timeout error of CAN-Receive-Frame ComRxTrbChActr
24122 65370 9
Timeout error of CAN-Receive-Frame ComRxUQSens
24123 65371 9
Timeout error of CAN-Receive-Frame ComSCRHtCtl
24124 65372 9
Timeout error of CAN-Receive-Frame ComTxAT1IMG
24125 65373 9
Timeout error of CAN-Receive-Frame ComTxTrbChActr
24141
7
DEF dosing valve, dosing valve blocked
24147
7
SCR System, reverting valve blocked
13
SCR System, pressure build up not possible
24152
2
Urea Quality Sensor, Timout CAN message
24153
2
Urea tank level & urea tank temperature via CAN bus, timeout of CAN message
24156
9
Timeout error of CAN-Receive-Frame ComRxEBC2
24175
0
SCR-CAT, Nox emissions above minimum threshold
24177
7
SCR System, DEF suction line blocked
24178
7
SCR System, DEF pressure ot of range
24190
14
Not enough urea in tank or low urea quality or hardware tampering failure is detected or
hardware failure is detected
24191
14
A low DEF tank level or a low DEF quality is detected or hardware tampering or hardware
failures
24193
8
The standstill-regeneration mode time exceeds the long limit threshold; Vehicle was too long or
too often in standstill mode; Change oil and reset counter
24194
8
The standstill-regeneration mode time exceeds the short limit threshold; Vehicle was too long or
too often within a short time in standstill mode; Change oil and reset counter
24195
14
Standstill request due to crystalization ignored too long
104
GTH-1056
April 2017
Part No. 1278145

Hide quick links:

Advertisement

Table of Contents
loading