Perkins 1104 Engine Fault Codes
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
FMI
Description
653
2
Cylinder #3 injector data incorrect
5
Cylinder #3 injector open circuit
6
Cylinder #3 injector short
7
Cylinder #3 injector not responding
654
2
Cylinder #4 injector data incorrect
5
Cylinder #4 injector open circuit
6
Cylinder #4 injector short
7
Cylinder #4 injector not responding
678
3
8V DC supply short to battery positive
(+)
4
8V DC supply shorted to ground
723
8
Secondary engine speed signal
abnormal
1188
5
Turbo wastegate drive current low
1196
9
Machine security system module
non-communication
1347
5
Fuel rail pump output current low
6
Fuel rail pump output current high
7
Fuel rail pressure valve solenoid not
responding
2882
2
Mode selector switch: data
erratic/intermittent or incorrect
3509
3
5V DC power supply sensor short to
battery positive (+)
4
5V DC power supply sensor short to
ground