Deutz TCD3.6 Engine Fault Codes
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
23917 65165 0
Physical range check high for DV1 & DV2 upstream pressure; shut off regeneration
1
Physical range check low for DV1 & DV2 upstream pressure; shut off regeneration
2
Sensor DV1 & DV2 upstream pressure; plausibility error
3
Sensor error DV1 & DV2 upstream pressure; signal range check high
4
Sensor error DV1 & DV2 upstream pressure; signal range check low
23918 65166 0
Physical range check high for DV1 & DV2 upstream temperature; shut off regeneration
1
Physical range check low for DV1 & DV2 upstream temperature; shut off regeneration
2
Sensor DV1 & DV2 upstream temperature; plausibility error
3
Sensor error DV1 & DV2 upstream temperature; signal range check high
4
Sensor error DV1 & DV2 upstream temperature; signal range check low
23919 65167 0
Physical range check high for airpump pressure; shut off regeneration
1
Physical range check low for airpump pressure; shut off regeneration
2
Sensor airpump pressure; plausibility error
3
Sensor error airpump pressure; signal range check high
4
Sensor error airpump pressure; signal range check low
23920 65168 0
Physical range check high for exhaustgas back pressure burner; shut off regeneration
1
Physical range check low for exhaustgas back pressure burner; shut off regeneration
2
Sensor exhaustgas back pressure; plausibility error
3
Sensor error exhaustgas back pressure burner; signal range check high
4
Sensor error exhaustgas back pressure burner; signal range check low
23921 65169 0
Physical range check high for burner temperature
1
Physical range check low for burner temperature
2
Sensor burner temperature; plausibility error
3
Sensor error burner temperature; signal range check high
4
Sensor error burner temperature; signal range check low
11
Sensor burner temperature; plausibility error
23922 65170 3
Burner shut of valve; short circuit to battery
4
Burner shut of valve; short circuit to ground
5
Burner shut off valve; open load
7
Shut off valve: blocked
12
Over temperature error on burner shut of valve
96