Deutz TCD3.6 Engine Fault Codes
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
24065
0
Pressure sensor upstream SCR-CAT, pressure above upper physical threashold
1
Pressure sensor upstream SCR-CAT, pressure below lower physical threashold
2
Pressure sensor upstream SCR-CAT, plausibility error
3
Pressure sensor upstream SCR-CAT, short circuit battery or open load
4
Pressure sensor upstream SCR-CAT, short circuit ground
24067
0
DEF supply module, heater temperature above upper physical threshold
1
DEF supply module, heater temperature below lower physical threshold
2
Supply module heather temperature, plausibility error
24068 65316 2
Master ECU and Slave ECU have been identified as the same types
24069 65317 9
Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO; Master-Slave CAN communication
faulty
24074
9
NOx sensor downstream SCR-CAT, sensor internally open load
24075
11
NOx sensor downstream SCR-CAT, sensor internally short circuit
24076
9
NOx sensor downstream SCR-CAT, sensor internally open line
24077
11
NOx sensor upstream SCR-CAT, sensor internally short circuit
24078
9
NOx sensor downstream SCR-CAT, lambda value above upper physical threshold
24079
9
NOx sensor downstream SCR-CAT, lambda value below lower physical threshold
24080
9
NOx sensor upstream SCR-CAT, lambda value above upper physical threshold
24081
9
NOx sensor upstream SCR-CAT, lambda value below lower physical threshold
24083
9
NOx sensor downstream SCR-CAT, NOx value below minimum value
24085
9
NOx sensor upstream SCR-CAT, NOx value below lower physical threshold
102