SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
23911 65159 0
Burner dosing valve (DV2); overcurrent at the end of the injection phase
3
Burner dosing valve (DV2); short circuit to battery
4
Burner dosing valve (DV2); short circuit to ground
7
Burner dosing valve (DV2); blocked closed
11
Burner dosing valve (DV2); short circuit high side powerstage
12
Burner dosing valve (DV2); powerstage over temperature
23912 65160 0
Physical range check high for burner dosing valve (DV2) downstream pressure; shut off
regeneration
1
Physical range check low for burner dosing valve (DV2) downstream pressure; shut off
regeneration. When burner injector is actuated, the measured pressure does not rise above ca.
1250mbar abs (expected: ca. 2400mbar).
2
Burner dosing valve (DV2) downstream pressure sensor; plausibility error
3
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range check high
4
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range check low
23913 65161 3
Sensor error glow plug control diagnostic line voltage; signal range check high
4
Sensor error glow plug control diagnostic line voltage; signal range check low
23914 65162 3
Glow plug control; short circuit to battery
4
Glow plug control; short circuit to ground
5
Glow plug control; open load
11
Glow plug control; internal error
12
Glow plug control; powerstage over temperature
23915 65163 0
HCI dosing valve (DV1); overcurrent at the end of the injection phase
3
HCI dosing valve (DV1); short circuit to battery
4
HCI dosing valve (DV1); short circuit to ground
7
HCI dosing valve (DV1); blocked
11
HCI dosing valve (DV1); short circuit high side powerstage
12
HCI dosing valve (DV1); powerstage over temperature
23916 65164 0
Physical range check high for HCI dosing valve (DV1) downstream pressure; shut off
regeneration
1
Physical range check low for HCI dosing valve (DV1) downstream pressure; shut off
regeneration
2
Sensor HCI dosing valve (DV1) downstream pressure; plausibility error
3
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check high
4
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check low