Service and Repair Manual
Deutz TCD3.6 Engine Fault Codes
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
23943 65191 9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1OGCVol2 information; factors &
Sensorcalibration for NOX Sensor (SCR-system downstream cat; DPF- system downstream
cat)
23946 65194 0
Zerofuel calibration injector 1 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 1 (in firing order); minimum value exceeded
23947 65195 0
Zerofuel calibration injector 2 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 2 (in firing order); minimum value exceeded
23948 65196 0
Zerofuel calibration injector 3 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 3 (in firing order); minimum value exceeded
23949 65197 0
Zerofuel calibration injector 4 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 4 (in firing order); minimum value exceeded
23950 65198 0
Zerofuel calibration injector 5 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 5 (in firing order); minimum value exceeded
23951 65199 0
Zerofuel calibration injector 6 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 6 (in firing order); minimum value exceeded
23960 65208 0
EGR cooler downstream temperature; out of range, system reaction initiated
1
EGR cooler downstream temperature; out of range, system reaction initiated
Exhaust gas temperature EGR downstream; out of range, system reaction initiated
Exhaust gas temperature EGR downstream; out of range, system reaction initiated
23973 65221 14
SCR Tamper detection; derating timer below limit 1
23974 65222 14
SCR Tamper detection; derating timer below limit 2
23975 65223 14
Urea quality; derating timer below limit 1
23976 65224 14
Urea qulaity; derating timer below limit 2
23977 65225 14
Urea tank level; derating timer below limit 1
23978 65226 14
Urea tank level; derating timer below limit 2
23980 65228 14
Bad quality of reduction agent detected
23981 65229 11
Urea-tank without heating function (heating phase)
23982 65230 0
Powerstage diagnosis disabled; high battery voltage
1
Powerstage diagnosis disabled; low battery voltage
98
GTH-1056
April 2017
Part No. 1278145