23.4

Display function

Displaying the part timer
The part timer is available for the control system to count the following time periods:
Time
Run time
Cycle time
Cutting time
Setup time
1)
Power on time
1)
Remain time
2)
The remaining time has no corresponding system variable, and can be counted only after a cycle of a part program has
1)
successfully run.
Both the setup time and the power on time are counted automatically after the controller has been powered on.
2)
By default, the run time, the cycle time, the setup time and the power on time are displayed. The cutting time can only be
counted after being activated with MD27860:
No.
Name
27860
PROCESSTIMER_MODE
The procedure for calling the time counter is as follows:
Or
210
Corresponding system variable
$AC_OPERATING_TIME
$AC_CYCLE_TIME
$AC_CUTTING_TIME
$AN_SETUP_TIME
$AN_POWERON_TIME
-
1.
Select the offset operating area.
2.
Press these two softkeys in succession. Then the time counter can be displayed counting
following:
1.
Enter "AUTO" operating mode and select the machining operating area.
2.
After you press this softkey, the time counter can also be displayed counting the following:
Description
Total time for running programs in "AUTO" mode
Run time of a selected program
Cutting time (G01, G02, G03) of a selected program
Time elapsed since the last power-on with default val-
ues
Time elapsed since the last normal power-on
Remaining time for running the current program.
Value
Descriptions
Actual value
Activation of counting for following program runtime:
Run time
Cycle time
Cutting time