Block-Search Response; Description Of Auxiliary Functions; M Function - Siemens SINUMERIK 808D Function Manual

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Configuring example:
Distribute 8 auxiliary functions to 7 groups:
Group 1: M0, M1, M2 (M17, M30) - by default, should be kept
Group 2: M3, M4, M5 (M70) - by default, should be kept
Group 3: S functions - by default, should be kept
Group 4: M78, M79
Group 5: M80, M81
Group 6: H1=10, H1=11, H1=12
Group 7: all T functions
Password for protection level 1 is set.
Make entry in MD11100 AUXFU_MAXNUM_GROUP_ASSIGN=8.
Then turn off the control and turn it on again or perform the control start-up through the softkey and define the remaining
machine data with a subsequent restart of the control.
The table below shows the examples of entries into the machine data:
Index n
MD22000
(GROUP)
0
4
1
4
2
5
3
5
4
6
5
6
6
6
7
7
9.5

Block-search response

Block search with calculation
For the block search with calculation all auxiliary functions that are assigned to a group are collected and are issued at the
end of the block search before the actual re-entry block (except for group 1: M0, M1,...). The last auxiliary function of a group
is issued.
All collected auxiliary functions are issued in a separate block as regular auxiliary functions and before the movement.
Note
If the auxiliary functions are to be collected during the block search, they must be assigned to an auxiliary function group!
9.6

Description of auxiliary functions

9.6.1

M function

Application
You can use the M functions to enable the various switching operations on the machine per part program.
Scope of functions
● Five M functions per part program block are possible.
● Value range of M functions: 0 to 99; integer number
74
MD22010
(TYPE)
M
M
M
M
H
H
H
T
MD22020
(EXTENSION)
0
0
0
0
1
1
1
0
MD22030
(VALUE)
78
79
80
81
10
11
12
-1
Function Manual
01/2017

Advertisement

Table of Contents
loading

Table of Contents