23.9

Using the machine manufacturer's R variable names

If necessary, you can define the names of the R variables as desired.
Proceed as follows to define your own R variable names:
After you have defined at least one R variable name on the control system, you can find an OEM R variable name file (.txt)
which contains the manufacturer's R variable names defined under the current system language. You can access this file
through the following operations:
+
An OEM R variable name file is language-dependent. You can copy the file in the desired language to your computer using
a USB memory stick for backup or batch editing of the R variable names.
224
1.
Select the offset operating area.
2.
Press this softkey to open the list of R variables.
3.
Press this softkey to activate the name display of all R variables.
4.
Use the cursor keys to select an R variable and enter the desired name in the name input
field, for example:
5.
Press this key or move the cursor to confirm your entries.