13.4 Check inlet pressure.

The appliance is pre-set to give the correct heat input at the inlet pressure shown in
section 4 of this guide. No adjustment is necessary.
1. Ensure that the fire is OFF then fit a pressure gauge at the test point. The test
point is on the inlet 'T' connector (See figure 22). Turn the fire ON and check the
pressure with the appliance alight and set at maximum output.
2. After checking, turn off the appliance. Remove the pressure gauge and replace the
test point sealing screw.
3. Test around the sealing screw for gas soundness with a suitable leak detection
fluid.
Figure 22. Pressure test point

14. FITTING THE CERAMIC FUEL EFFECT

Before continuing ensure that the burner is OFF. Wait a few minutes for the
convection box and burner to cool completely. To prevent unexpected burner
operation, it is advisable to either remove the batteries from the remote control
handset or place the handset away from the work area and out of reach of children.
The ceramic walls have a plain and patterned side. Ask the customer which they
prefer.

14.1 Fitting the rear ceramic wall.

Locate the rear ceramic wall against the rear wall of the convector box.

14.2 Fitting the side ceramic walls.

Offer the ceramic side walls into the convection box. The bottom of the ceramic side
walls should be located first (See figure 23). With the bottom in place gently lift the
side wall until it is flat against the side of the convection box (See figure 24).

14.3 Fitting the ceramic support.

Locate the ceramic support to the base of the burner tray using three No.8 x 3/8"
screws supplied (See figure 24).
©