Request Sense
Unit Attention Sense Key
The library generates a Unit Attention sense key for all initiators if the library
needs to inform the host of an asynchronous event. The following pages describe
library conditions that generate Unit Attention errors.
TABLE 6-89 Unit Attention Sense Keys
Description
Power-On Occurred
SCSI Bus Reset
Bus Device Reset Message
LUN Reset
Target Reset
Not Ready-to-Ready Transition
CAP Element Accessed
Mode Parameters Changed
Reservations Preempted
Reservations Released
Registrations Preempted
Microcode Has Been Changed
LUN Data Has Changed
Power On
The library generates this type of Unit Attention when the library is powered-on,
IPLed from the operator panel, or reset over the interface. A Unit Attention is
generated for all initiators.
SCSI Bus Reset
The library generates this type of Unit Attention to all initiators after the SCSI bus
is clear of all I/O processes following a hard reset.
Bus Device Reset Message
The library generates this message to all initiators after the library is clear of all
I/O processes following a hard reset.
LUN Reset
The library generates this type of Unit Attention to all initiators after the library is
clear of all I/O processes following the LUN reset.
216 SL500: Interface Reference Manual • July 2008
Sense Key
ASC
6h
29h
6h
29h
6h
29h
6h
29h
6h
29h
6h
28h
6h
28h
6h
2Ah
6h
2Ah
6h
2Ah
6h
2Ah
6h
3Fh
6h
3Fh
Revision: F • 96122
ASCQ
01h
02h
03h
03h
03h
00h
01h
01h
03h
04h
05h
01h
0Eh