Send Diagnostic

Send Diagnostic Data

For extended diagnostics, the initiator must provide Send Diagnostic parameter
data in a parameter list that include.
A page code
Diagnostic parameters

TABLE 6-97 Send Diagnostic Data

Byte
7
0
1
2
(MSB)
to
3
4
(MSB)
to
7
Send Diagnostic Data Definitions:
Page Code
Page Length
Diagnostic Parameters

Diagnostic Operations

Because the Receive Diagnostic command is not supported, check the error log
(also referred to as the events log) following a diagnostic failure. This provides
specific details of the error. The error log is available via a log sense command or
from the operator panel.
The uncalibrate diagnostic (page code 90h) uncalibrates all target data. This forces
the library to recalibrate during subsequent operations.
Note – The library generates a Not Ready to Ready Unit Attention Sense Key for
all other initiators after diagnostic operations have completed.
228 SL500: Interface Reference Manual • July 2008
6
5
4
Page Code
Reserved (00h)
Page Length (0004h)
Diagnostic Parameters
This field specifies which extended diagnostic test is to be executed:
90h = Uncalibrate
This field specifies the number of bytes in the parameter list, which follows.
The value is always 0004h.
This field is reserved and is set to 0h.
Bit
3
2
1
0
(LSB)
(LSB)
Revision: F • 96122