Class of Service Parameters
Fibre Channel provides several different strategies to ensure reliable
communications between devices. These strategies are called Classes of Service.
The libraries support the Class 3 level of service which provides no notification of
frame delivery or non-delivery. This class of service reduces the number of frames
(traffic) on the loop.
The start-of-frame (SOF) delimiter specifies the type of service used for each frame
during communications.
TABLE 5-6
TABLE 5-6 Start of Frame Delimiters, Class 3
Delimiter
SOF Initiate Class 3
SOF Normal Class 3
Note: Intermixing different classes of service is not supported.
The libraries adhere to a set of operating characteristics that ensure
inter-operability and reliability within a Class 3 loop environment are maintained.
TABLE 5-7 on page 54
■
TABLE 5-8 on page 55
■
96122 • Revision: F
indicates the two types of delimiters for Class 3 operations.
Abbreviation
SOFi3
SOFn3
lists the
Class 3 Service Parameters, Port Login
lists the
Class 3 Service Parameters, Fabric Login
Transmission Word Characters
K28.5
D21.5
K28.5
D21.5
Chapter 5 Fibre Channel Operations 53
FC-2 Features
D22.2
D22.2
D22.1
D22.1
(PLOGI)