Send Diagnostic; Table 6-96 Send Diagnostic Command - Sun Microsystems storagetek sl500 Reference Manual

Modular library system
Hide thumbs Also See for storagetek sl500:
Table of Contents

Advertisement

Send Diagnostic

The Send Diagnostic command (1Dh) requests the library to perform a self-
diagnostic test. The library may support some self tests in the future but for now
considers this command to be a no-operation.
The self-test includes initialization diagnostics and calibration of the library. The
extended diagnostics provide random cartridge motions and additional calibration
features.
The library disconnects while a diagnostic test is being performed, then reconnects
when the diagnostic test completes. This disconnected time can be several minutes,
and time- outs should be adjusted accordingly.
The library returns status based on the diagnostic test result. The Receive
Diagnostic command is not used.

TABLE 6-96 Send Diagnostic Command

Byte
7
0
1
2
3
(MSB)
to
4
5
Send Diagnostic Command Descriptions:
PF
SelfTest
DevOfl
UnitOfl
Parameter List Length
96122 • Revision: F
6
5
Operation Code (1Dh)
Ignored
Parameter List Length
Control Byte (00h)
The library supports the page format (PF) specified by SCSI-3.
The value of PF should be 1. However, the library accepts a 0 for self test.
The library returns a value of 1, indicating a request to the library to complete
the library's default test.
This feature is not supported by the library; the value is set to 0.
This feature is not supported by the library; the value is set to 0.
For the self-test option, a value of 0h is required.
For extended diagnostics, a value of 8h is required. (not supported)
Bit
4
3
PF
Rsvd
SelfTest
(0)
(1)
Reserved (00h)
Chapter 6 SCSI Commands 227
Send Diagnostic
2
1
0
DevOfl
UnitOfl
(0)
(0)
(LSB)