Tapealert Flags; Table 6-18 Tapealert Flags - Sun Microsystems storagetek sl500 Reference Manual

Modular library system
Hide thumbs Also See for storagetek sl500:
Table of Contents

Advertisement

Informational Exceptions TapeAlert Page Definitions:
Parameter Code
DU
DS
TSD
ETC
TMC
LBIN
LP
Parameter Length
Flag

TapeAlert Flags

TABLE 6-18
in sequential order,
have valid values of 0 (off) or 1 (on)
reports all 32
Type codes indicate:
C = Critical,
W = Warning,
I = Informational.

TABLE 6-18 TapeAlert Flags

Code
Flag Name
0001h
Library Hardware A
0002h
Library Hardware B
0003h
Library Hardware C
0004h
Library Hardware D
0005h
Library Diagnostics
Required
0006h
Library Interface
0007h
Predictive Failure
0008h
Library Maintenance
96122 • Revision: F
A 2-byte field which represents the TapeAlert Flag number.
Disable Update is always 0, which indicates that the target updates the log
parameter value instead of the initiator.
Disable Save is always 1, which indicates saving the log is not supported.
Target Save Disable is always 0.
Enable Threshold Comparison is always 0.
Threshold Met Criteria is always 0.
The library returns 0 indicating it is not used.
List Parameter is always 0, which indicates the log parameter is a data counter.
Parameter Length is always 0x01. All are 1-byte flags.
A value of 0x01 indicates that the flag the Parameter Code is pointed to is
active; all other values are off.
lists information about the TapeAlert flags. Flags are:
Description
Set when the library cannot communicate with a tape
drive. This does not cause the library to stop operating.
Set when the servo control mechanism breaks lock.
The various causes are when the hand positioning on
the column fails or when the hand fails.
Set when the library has a hardware fault.
Set when camera initialization, calibration, or
mechanical initialization test fails.
Set when the library might have a hardware fault.
Set when a corrupted SCSI command is sent to the
library from an initiator. Currently, this flag is set
when a parity error is detected on the SCSI bus.
Set when a library hardware failure is predicted.
Set when preventive maintenance is required.
Log Sense
Type
Chapter 6 SCSI Commands 103
C
W
C
C
W
C
W
W