Replacing a Unit

When replacing a unit, you must power the failed unit down, remove and reinstall
the cabling, cover, and feet onto the new unit, and power the new unit on.
Note – If you are replacing a rackmount unit, unscrew the unit from the shelf, slide
the unit out, and follow the steps below. See Section 1.2.1, "Mounting the
Autoloader," on page 1-7 for more details.
1. Remove all tapes from the failed unit. See Section 3.2, "Loading/Unloading Tape
Cartridges Into the Autoloader," on page 3-2.
2. If the failed unit is still powered on, turn the standby (power) switch off, which is
in the bottom left-hand corner when you are facing the unit, and unplugging the
power cord.
3. Remove the cabling and terminator from the back of the failed unit.
4. Remove the cover and feet from the failed unit.
a. On the failed unit, remove the four screws on the back of the cover and the two
screws on the side of the cover (
b. Remove the cover by pulling the sides slightly out and lifting the cover up and
toward the back of the unit (
c. Unscrew and remove the four feet. You can lay the unit on its side to remove
the feet.
Tip – If the cover fits tightly near the display and is not easily removed, pull the
sides out near the display panel while rotating the the cover up.
5-2
StorEdge L280 Service Manual • February 1998
on page 5-3).
FIGURE 5-1
on page 5-3).
FIGURE 5-2