8 S-45: Press down the foot switch. Activate the
jib boom toggle switch in the down position, hold
for a moment and then release it.
Result: The descent alarm should sound when
the switch is held down.
9 Press down the foot switch. Move the drive
control handle off center, hold for a moment and
then release it. Move the drive control handle off
center in the opposite direction, hold for a
moment and then release it.
Result: The travel alarm should sound when the
drive control handle is moved off center in either
direction.
Part No. 826364
B-18

Perform Hydraulic Oil Analysis

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
may cause the machine to perform poorly and
continued use may cause component damage.
Extremely dirty conditions may require oil changes
to be performed more often. For hydraulic oil
specifications, refer to Section 2, Specifications .
Note: Before replacing the hydraulic oil, the oil may
be tested by an oil distributor for specific levels of
contamination to verify that changing the oil is
necessary. If the hydraulic oil is not replaced at
the two year inspection, test the oil quarterly.
Replace the oil when it fails the test.
See E-1, Test or Replace the Hydraulic Oil.
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
3 - 31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45 traxS-45

Table of Contents