Genie S-40 Service Manual page 74

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
29 Using a suitable lifting device, remove all weight
from the platform. Note the result on the
multimeter.
Result: The readout on the multimeter should
indicate infinite resistance.
Result: The readout on the multimeter shows
zero resistance. Remove the machine from
service and contact the Genie Service
Department .
31 Turn off the multimeter and remove the leads
from the machine. Securely connect the wires
disconnected in step 27.
32 Close the platform control box. Install and
securely tighten the fasteners. Do not
overtighten.
3 - 40
C-3
Replace the Engine Air Filter
Element
Genie specifications requires that this procedure be
performed every 500 hours or 6 months, whichever
comes first.
Maintaining the engine air filter in good condition is
essential to good engine performance and service
life. Failure to perform this procedure can lead to
poor engine performance and component damage.
1 Open the evacuator valve located on the air
2 Disconnect the latches on the air cleaner cap.
3 Remove the filter element.
4 Clean the inside of the canister and the gasket
5 Install the new filter element.
6 Install the end cap on the canister and re-
Note: Be sure the evacuator valve is pointing down.
S-40 • S-45 • S-40 TRAX • S-45 TRAX
cleaner cap by squeezing the sides together
with your fingers.
Remove the end cap from the air cleaner
canister.
with a damp cloth.
connect the latches.
October 2014
Part No. 826364

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45 traxS-45

Table of Contents