Perform Engine Maintenance - Deutz Models - Genie S-40 Service Manual

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
C-6
Perform Engine Maintenance -
Deutz Models
Engine specifications require that this procedure be
performed every 500 hours.
All models:
Engine oil- replace
Oil filter- replace
D 2.9 L4 Models:
Engine coolant- test/add
Air intake pipes- inspect
V-belts- inspect
Fuel filter / separator- replace
Required maintenance procedures and additional
engine information are available in the
Deutz 2011 Series Operation Manual
(Deutz part number 0312-3547) OR the
Deutz 2.9 L4 Series Operation Manual
(Deutz part number 3012-3893)
Deutz 2011 Series Operation Manual
Genie part number
Deutz 2.9 L4 Series Operation Manual
Genie part number
3 - 42
C-7
Check and Adjust the
Engine RPM
Genie specifications require that this procedure be
performed every 500 hours.
Maintaining the engine rpm at the proper setting for
both low and high idle is essential to good engine
performance and service life. The machine will not
operate properly if the rpm is incorrect and
continued use may cause component damage.
Note: This procedure will require two people.
Ford MSG-425 Models
Deutz D 2.9 L4 Models
Perkins 404F-22 Models
Not applicable to these models.
Note: The engine rpm is controlled by the ECM and
can only be adjusted by re-programming the ECM.
If rpm adjustment or service is required, please
contact Genie Service Department.
Deutz D2011L03i Models
139320
1 Connect a tachometer to the engine. Start the
1251561
S-40 • S-45 • S-40 TRAX • S-45 TRAX
engine from the ground controls. Refer to
Section 2 , Specifications.
October 2014
Part No. 826364

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45 traxS-45

Table of Contents