Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
8 Test all machine functions from the platform
controls.
Result: All platform control functions should not
operate.
9 Turn the key switch to ground control.
10 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
11 Activate the auxiliary power toggle switch.
12 Using auxiliary power, test all machine functions
from the ground controls.
Result: All ground control functions should
operate.
13 Using a suitable lifting device, lift the additional
test weight from the platform.
Result: The platform overload indicator lights
should turn off at both the ground and platform
controls and the alarm should not sound.
14 Start the engine and test all machine functions
from the ground controls.
Result: All ground control functions should
operate normally.
15 Turn the key switch to platform control.
3 - 38
16 Test all machine functions from the platform
Note: If the platform overload system is not
operating properly, Refer to Repair Procedure 2-4,
How to Calibrate the Platform Overload System (if
equipped).
17 Push in the red Emergency stop button at the
18 Using a suitable lifting device, remove all test
19 Pull out the red Emergency stop button to the on
20 Remove the fasteners securing the lid to the
S-40 • S-45 • S-40 TRAX • S-45 TRAX
controls.
Result: All platform control functions should
operate.
platform to shut off engine.
weights from the platform.
position at the platform controls.
platform controls. Using Illustration 2 as a
guide, locate the timer relay inside the platform
control box. Tag and disconnect the red wire
from terminal 5 on the timer relay.
Timer Relay
Terminal 5
Illustration 2
October 2014
Orange
Wire
Part No. 826364