Checklist B Procedures
B-16
Test the Alarm and Flashing
Beacon
Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
An alarm and/or flashing beacon are installed to
alert operators and ground personnel of machine
proximity and motion. There are four alarm option
modes that can be activated based on user
preference or requirement. Refer to Display
Module in the Repair Section for information.
1
Turn the key switch to ground controls and
pull out the red Emergency Stop button to the
on position at both ground and platform
controls.
Result: The alarm should sound twice. The
flashing beacon should be on and flashing.
46
B-17

Perform Hydraulic Oil Analysis

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
may cause the machine to perform poorly and
continued use may cause component damage.
Extremely dirty conditions may require oil changes
to be performed more often. For hydraulic oil
specifications, refer to Specifications, Hydraulic
Specifications.
Note: Before replacing the hydraulic oil, the oil may
be tested by an oil distributor for specific levels of
contamination to verify that changing the oil is
necessary. If the hydraulic oil is not replaced at the
two year inspection, test the oil quarterly. Replace
the oil when it fails the test. Refer to Maintenance
Procedure, Test or Replace the Hydraulic Oil.