Section 4 • Repair Procedures
PLATFORM CONTROLS
12 While the joystick is activated, set the ramp
rate. Momentarily move the drive enable toggle
switch in the right direction to increase the time
or momentarily move the drive enable toggle
switch in the left direction to decrease the time.
Note: Each time the drive enable toggle switch is
momentarily moved, the time will change in 5%
increments.
13 Repeat steps 9 through 11 for each joystick
controlled machine function.
14 Return the joystick to the neutral position and
wait for approximately 10 seconds to allow the
settings to be saved.
Result: The alarm should sound indicating that
the settings have been saved in memory.
Note: Do not operate any machine function during
the 10 second waiting time.
15 Cycle the red Emergency Stop button off, then
back on.
4 - 6
Ramp rate (factory settings)
Boom up/down
accelerate
decelerate
Turntable rotate
accelerate
decelerate
Drive
accelerate
decelerate to neutral
decelerate, change of direction
decelerate, coasting
decelerate, braking
decelerate, shift from low to high speed
decelerate, shift from high to low speed
S-40 • S-45 • S-40 TRAX • S-45 TRAX
February 2014
3 second
1 seconds
2 seconds
1 second
2 seconds
0.5 second
0.5 second
0.75 second
1 second
1 second
3 seconds
Part No. 826364