Fault Code Display - Flashing And Solid Led's - Genie S-40 Service Manual

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

February 2014
1
2
3
1 Left green LED:
Flashing, engine fault detected. Contact service.
Solid, fault acknowledged. Contact service.
2 Left amber LED: (Perkins models)
Solid,
a) Regeneration is inhibited. No service required.
b) High exhaust temperature during regeneration mode. No service required.
3 Left red LED:
Flashing, engine fault detected. Contact service.
Flashing with right flashing amber LED, engine soot level over 140%. Engine shut down. Contact
service.
4 Right green LED:
Flashing, engine fault detected. Contact service.
Solid, fault acknowledged. Contact service.
5 Right amber LED: (Perkins models)
Solid with left amber LED on solid, regeneration has been inhibited and engine soot level is between
80 - 100%. Regeneration is required.
Flashing with left amber LED on solid, regeneration has been inhibited and soot level is between
100 - 140%. Engine rpm is de-rated. Regeneration is required.
Flashing with left and right red LED's flashing, engine soot level over 140%. Engine shut down. Contact
service.
6 Right red LED:
Flashing, engine fault detected. Contact service.
Flashing with right flashing amber LED, engine soot level over 140%. Engine shut down. Contact
service.
Part No. 826364
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Section 5 • Fault Codes
Fault Code Display -
Flashing and Solid LED's
4
5
6