Fault Code Chart - Genie GS-2669 RT Service Manual

Hide thumbs Also See for GS-2669 RT:
Table of Contents

Advertisement

November 2014
Error Source
ID
Name
01
Internal ECU Fault N/A
02
Platform ECU
Fault
20
Chassis Start
Switch
21
Chassis Choke
Switch
22
Chassis Up Switch N/A
23
Chassis Lift
Switch
24
Down Switch
25
Left Turn Switch
26
Right Turn Switch N/A
27
Drive Enable
Switch
Part No. 229753
Error Type
ID
Name
Internal ECU error. System shutdown.
N/A
Platform / Ground System shutdown.
communication
error.
N/A
Engine start
button fault at
ground controls.
N/A
Starting aid
button fault at
ground controls.
Platform up
switch fault at
ground controls.
N/A
Platform up/down Platform up/down
enable button fault functions disabled.
at ground controls.
N/A
Platform down
switch fault at
ground controls.
N/A
Left turn switch
fault.
Right turn switch
fault.
N/A
Function enable
switch activated
when machine is
powered on.
GS-2669 RT • GS-3369 RT • GS-4069 RT

Fault Code Chart

Condition
Engine will not
start.
Starting aid
disabled.
Platform up
disabled.
Platform down
disabled.
Malfunctioning steer
left microswitch.
Malfunctioning steer
right microswitch.
Machine functions
disabled.
Section 5 • Fault Codes
Solution
Replace ECU.
Troubleshoot control
cable or platform
controls.
Replace ECU.
Replace ECU.
Replace ECU.
Replace ECU.
Replace ECU.
Troubleshoot steer
left microswitch.
Troubleshoot steer
right microswitch.
Release function
enable switch before
power up or replace
joystick.
5 - 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-4069 rtGs-3369 rt