Table 2–4 (Cont.): 2200 Setup, Feature, and Value Menus
Setup
Feature
Level
Level
INTERFACE
i/f
1
baud
rsmode
1
dtr
1
This value appears only if you select RS232C.
The LOAD<– ROM factory values are in bold.
The equal (=) sign indicates the selected value. When you scroll into a value level, the selected
value is displayed first.
Value
Level
Comment
=RS232C
If you select CENTRO, the parallel 8-bit
CENTRO
Centronics port is activated. There are
no features or values associated with the
CENTRO selection. All speeds and signals
are fixed.
If you select RS232C, the serial RS232C
compatible port is activated.
The following parameters are always
printed on the Test Print A sheet, but are
displayed only when RS232C is selected.
19200
Establishes the baud rate of the serial
9600
port. The baud rate of the printer must
4800
match the baud rate of the host system.
=2400
1200
600
300
1
8S
The values define the characteristics of the
8SS
RS232C serial data byte and must match
=7OS
the host system. The following example
7ES
shows the format:
7OSS
7ESS
8OS
8ES
READY-H
Sets the state of the serial connector DTR
=Fix–H
signal to be fixed or conditional to the
online ready state of the printer.
DEClaser 2200 Control Panel Operation
baud
rsmode
dtr
xon/xoff
etx/ack
8OS
where:
8 is the number of data bits.
O means odd parity, E means
even parity, no O or E means no
parity checking.
S means one stop bit is used.