Communication Setup; Communication Port - Christie DWU1052 User Manual

Q series
Hide thumbs Also See for DWU1052:
Table of Contents

Advertisement

7. Network Bridge Function

7.2 Communication setup

To configure the setup of the communication using NETWORK BRIDGE for
the projector, use items in the COMMUNICATION menu. Open the menu of
the projector and select the OPTION - SERVICE - COMMUNICATION menu.
(&OPTION menu > SERVICE > COMMUNICATION in the Operating Guide)
1) In the COMMUNICATION TYPE menu, select NETWORK BRIDGE
(WIRELESS or WIRED depending on the type of connection you use) for the
CONTROL port.
2) Using the SERIAL SETTINGS menu, select the proper baud rate and parity
for the CONTROL port, according to the specification of the RS-232C port of
the connected device.
BAUD RATE
Data length
3) Using the TRANSMISSION METHOD menu, set up the proper method for the
CONTROL port according to your use.
NOTE
• The OFF is selected for the COMMUNICATION TYPE as the default
setting.
• Using the COMMUNICATION menu, set up the communication. An unsuitable
setup could cause malfunction of communication.
• When either one of the NETWORK BRIDGE settings is selected in the
COMMUNICATION TYPE menu, RS-232C commands cannot be received from
the CONTROL port.

7.3 Communication port

For the NETWORK BRIDGE function, send the data from the computer to the
projector with using the Network Bridge Port configured in the Port Settings of
web browser. (&47)
NOTE
• Except for 41794, 9715, 9716, 9719, 9720, 5900, 5500, 4352
between 1024 and 65535 can be set up as the Network Bridge Port number. It
is set to 9717 as the default setting.
DWU1052/DHD1052
User's Manual - Network Guide
Item
4800bps/9600bps/19200bps/38400bps
PARITY
NONE/ODD/EVEN
8 bit (fixed)
Start bit
1 bit (fixed)
Stop bit
1 bit (fixed)
Condition
86
020-000855-01 Rev.1 (12-2015)
LIT MAN USR DWU/DHD1052 NET

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhd1052

Table of Contents