Configuring The Minimum Oper Up Links In A Port Channel - Dell S4820T Configuration Manual

Hide thumbs Also See for S4820T:
Table of Contents

Advertisement

Dell(conf-if-po-3)#sho conf
!
interface Port-channel 3
no ip address
channel-member TenGigabitEthernet 1/8
shutdown
Dell(conf-if-po-3)#

Configuring the Minimum Oper Up Links in a Port Channel

You can configure the minimum links in a port channel (LAG) that must be in "oper up" status to consider
the port channel to be in "oper up" status.
To set the "oper up" status of your links, use the following command.
Enter the number of links in a LAG that must be in "oper up" status.
INTERFACE mode
minimum-links number
The default is 1.
Example of Configuring the Minimum Oper Up Links in a Port Channel
Dell#config t
Dell(conf)#int po 1
Dell(conf-if-po-1)#minimum-links 5
Dell(conf-if-po-1)#
Configuring VLAN Tags for Member Interfaces
To configure and verify VLAN tags for individual members of a port channel, perform the following:
1.
Configure VLAN membership on individual ports
INTERFACE mode
Dell(conf-if)#vlan tagged 2,3-4
2.
Use the switchport command in INTERFACE mode to enable Layer 2 data transmissions through
an individual interface
INTERFACE mode
Dell(conf-if)#switchport
3.
Verify the manually configured VLAN membership (show interfaces switchport interface command).
EXEC mode
Dell(conf)# interface tengigabitethernet 1/1
Dell(conf-if-te-1/1)#switchport
Dell(conf-if-te-1/1)# vlan tagged 2-5,100,4010
Dell#show interfaces switchport te 1/1
Codes:
U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Trunk, H - VSN tagged
i - Internal untagged, I - Internal tagged, v - VLT untagged, V -
426