Dell S4820T Configuration Manual page 312

Hide thumbs Also See for S4820T:
Table of Contents

Advertisement

Description Link to RoCE Adapter in Blade Server
no ip address
mtu 12000
portmode hybrid
switchport
no spanning-tree
!
protocol lldp
dcbx port-role auto-downstream
no shutdown
!
interface fortyGigE 0/33
Description "To S4810s"
no ip address
mtu 12000
!
port-channel-protocol LACP
port-channel 1 mode active
!
protocol lldp
no advertise dcbx-tlv ets-reco
dcbx port-role auto-upstream
no shutdown
S4810 1 and S4810 2, VLT, RoCE, and iSCSI
!
dcb enable
iscsi enable
!
dcb-map converged
Description DCB map for S4810 interlinks
priority-group 0 bandwidth 30 pfc off
priority-group 1 bandwidth 40 pfc on
priority-group 2 bandwidth 30 pfc on
priority-pgid 0 0 0 1 2 0 0 0
!
dcb-map RoCE
Description DCB map for ports connected to RoCE NICs
priority-group 0 bandwidth 10 pfc off
priority-group 1 bandwidth 90 pfc on
priority-pgid 0 0 0 1 0 0 0 0
!
dcb-map iSCSI
Description DCB map for ports connected to iSCSI NICs
priority-group 0 bandwidth 10 pfc off
priority-group 1 bandwidth 90 pfc on
priority-pgid 0 0 0 0 1 0 0 0
!
interface fortyGigE 0/56
Description VLTi to other switch
S4810 1
312