Miscellaneous (Environmental) Discrete Telemetry Cable Installation - Alcatel-Lucent 1665 Installation Manual

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Equipment and cable installation
............................................................................................................................................................................................................................................................
Miscellaneous (environmental) discrete telemetry cable
installation
Description
The miscellaneous (environmental) discrete telemetry access allows the maintenance
center to control and monitor equipment collocated with the Alcatel-Lucent 1665 DMX
High-Capacity shelf.
The environmental control feature enables the maintenance center to remotely initiate up
to four contact closures at the remote terminal (RT) for equipment operation such as
pumps, generators, etc.
The environmental alarm status indications allow up to 23 miscellaneous user-settable
alarm status indications (SI) at the remote terminal for transmission toward the central
office.
Miscellaneous (environmental) discrete telemetry cable assemblies and the length options
are listed in
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
1
Connect the miscellaneous discrete telemetry cable to the J11 MISC connector on the
backplane of the Alcatel-Lucent 1665 DMX High-Capacity shelf per
"Miscellaneous discrete cable installation" (p.
............................................................................................................................................................................................................................................................
1 - 8 4
Table 1-27, "Miscellaneous discrete cable assemblies" (p.
Miscellaneous (environmental) discrete telemetry cable
1-85).
installation
1-86).
Figure 1-27,
365-372-304R7.1
Issue 2 March 2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents