Wdmx Setup And Testing: Integration Procedures - Alcatel-Lucent 1665 Installation Manual

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

WDMX setup and testing: integration procedures

............................................................................................................................................................................................................................................................
How to use this chapter
All of the sections in this chapter are stand alone procedures and are not intended to be
followed in any sequence. Locate the procedure in this chapter and follow the procedure
based on the requirements of the turn-up. When one procedure relies on steps from
another procedure or continues on with the next procedure, the link is provided in the
procedure.
Tools, test equipment and accessories
Listed below are the tools, test equipment and accessories necessary to perform the
procedures in this section.
Quantity
1
1
1
1
1
Prerequisite
The following is a list of items to verify before beginning tests in this section.
Two or more people are required to perform the end-to-end turn up in this section (one
at each adjacent node).
The office alarm cable will remain disconnected during this procedure.
Safety instructions
Note:
............................................................................................................................................................................................................................................................
7 - 2
Description
ESD Wrist Strap
OC-48 Test Set
Personal Computer (PC)
CIT Interface Cable
Optical Power Meter
All precautions should be observed when handling fiber.
Comments
A wrist strap must be worn when handling
circuit packs. Use the electrostatic discharge
(ESD) jack provided on the shelf.
An OC-48 test set is required for testing of
optical circuit packs. An Agilent OmniBER 718
or equivalent is recommended.
See
Chapter 3, "Software download and circuit
pack
installation",
PC minimum requirements
(p.
3-2).
8-ft. long RJ45 to 9-pin D-sub serial cable
(Comcode 848748869).
365-372-304R7.1
Issue 2 March 2008