Optical Test Set Arrangement; Transmission Rate - Alcatel-Lucent 1665 Installation Manual

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................
Figure 4-1 Optical test set arrangement
........................................................................................................................................................................................................................
5
Set the test set to the required rate for the packs under test. Refer to
Transmission
Table 4-4 Transmission rate
Test signal
mapping
Pattern
........................................................................................................................................................................................................................
6
Once the test set is in place, it will display pattern and AIS alarms. This is due to the fact
that we have not established a cross-connection. Enter a cross-connection either through
the GUI using the cross-connect wizard. Enter the command according to the optical pack
and function slot under test.
........................................................................................................................................................................................................................
7
Check the transmission at the test set. It should show no alarms. If alarms are present,
check the test set provisioning and the cross-connection to ensure they correspond to the
............................................................................................................................................................................................................................................................
4 - 6 0
Optical
TX
Test
Set
OC3
OC12
RX
OC48
rate.
OC-3
(LNW36,LNW37,
LNW45,LNW55)
STS-3C
2^23 -1 PRBS
RX
Standby
1x2
(FN-2)
splitter
TX
RX
Active
(FN-1)
TX
OC-48 (LNW31,LNW55,
OC-12
LNW62,LNW425, LNW427,
(LNW46,LNW49,
LNW447, LNW449, LNW453,
LNW55)
LNW455, LNW459)
STS-3C/12C
STS-3C/12C/48C
2^23 -1 PRBS
2^23 -1 PRBS
Additional optical tests (optional)
Table 4-4,
365-372-304R7.1
Issue 2 March 2008