Sync Cable Installation - Alcatel-Lucent 1665 Installation Manual

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Equipment and cable installation
............................................................................................................................................................................................................................................................

Sync cable installation

Description
This section provides the instructions for installing the two types of synchronization
(Sync) cables to the Alcatel-Lucent 1665 DMX High-Capacity shelf.
A Sync cable is required if the shelf is to be externally timed. The Alcatel-Lucent 1665
DMX High-Capacity shelf can provide DS1 external timing to a BITS clock. When the
shelf is externally timed by a DS1 Reference and/or is configured to provide a Sync
Output, a Sync Input timing cable is required.
This procedure should be performed on each Alcatel-Lucent 1665 DMX High-Capacity
shelf requiring an external timing source. There are two types of cables available:
1. Sync cable with a molded D-Sub 9-Pin (DB-9) connector
2. Sync cable with a wire-wrap DB-9 connector.
Note:
output (red) termination for timing. Refer to
timing reference) connections" (p. 1-77)
Sync cable with molded DB-9 connector procedure
Perform the following steps when using a Sync cable with a molded DB-9 connector.
........................................................................................................................................................................................................................
1
Connect the DB-9 connector end of the Sync cable to the SYNC1 (J9) port on the Alcatel-
Lucent 1665 DMX High-Capacity shelf backplane. Refer to
molded DB9 connector installation" (p.
............................................................................................................................................................................................................................................................
1 - 7 2
Each of the Sync connections on the backplane provides an input (gray) and
Table 1-24, "Synchronization cable (DS1
for the pinouts.
Figure 1-23, "Sync cable with
1-73).
Sync cable installation
365-372-304R7.1
Issue 2 March 2008