Equipment and cable installation
............................................................................................................................................................................................................................................................

DS3/EC1 and TMUX 48-port cable installation

Description
This section describes how to connect the DS3/EC1 and TMUX cables to the Alcatel-
Lucent 1665 DMX High-Capacity shelf and route the cables out of the bay and to the
DS3/EC1 terminating equipment. Perform this procedure if DS3/EC1 or TMUX cables
are required.
Note:
the DSX becomes an extension of the Alcatel-Lucent 1665 DMX High-Capacity shelf
backplane connections. Therefore, the IN on the Alcatel-Lucent 1665 DMX High-
Capacity shelf backplane connects to the IN of the DSX and the OUT of the Alcatel-
Lucent 1665 DMX High-Capacity shelf backplane connects to the OUT of the DSX.
DS3/EC1 and TMUX cable options are listed in
contains miscellaneous DS3 cables for both the 12-port and 48-port installations.
DS3/EC1 and TMUX transmission connections are in
groups fully cabled may have up to 192 DS3 drop capacity if using the 48-port DS3/EC1
or TMUX circuit packs.
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
1
Refer to the engineering job specification. Obtain the DS3 cables per
or
Table 1-11
indicating bay, shelf, function group (A, B, C or D) and direction (IN or OUT of the bay)
at each end.
Note:
(J1 - J8), the additional DS3 ports (25 - 48) are cabled to the middle section of the shelf
(J20 - J27).
........................................................................................................................................................................................................................
2
Connect the function group cables at the Alcatel-Lucent 1665 DMX High-Capacity shelf
end, carefully matching the correct connector with the appropriate backplane connectors
as shown in
Note:
of 6.5 in-lb. Do not overtighten.
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 2 March 2008
When cabling the Alcatel-Lucent 1665 DMX High-Capacity shelf to a DSX,
and note the function group where each cable will be used. Label the cables,
The first 24 ports of a Function unit must be cabled to the bottom connectors
Figure 1-14, "DS3/EC1 and TMUX cable installation" (p.
DS3/EC1 and TMUX cable retaining screws must be tightened to a maximum
DS3/EC1 and TMUX 48-port cable installation
Table 1-8
and
Table
1-9.
Table
1-11. A total of four function
Table
Table 1-10
1-8,
Table 1-9
1-42).
1 - 4 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents