Do not connect or disconnect AC power by inserting or removing the AC power
connector. Using the connector in this manner, even once, will damage the connector
making it unusable.

Auxiliary Logic/Alternate Power Wiring Supply

Auxiliary Power Supply (APS) allows the drive to retain motor position information and
serial communications when the main AC power supply is disconnected. You must reset the
drive, either using the reset button or a reset input, after AC power is re-applied if the backup
supplies have been active.
Auxiliary Logic Power Usage
)
Top View
Figure 13:
EN Auxiliary Power Supply Wiring Diagram
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Use 16 to 18 AWG stranded wire
Bus
+
J2
Bus
-V
- Auxiliary Supply
+ Auxiliary Supply
J3 - Two position header.
The mating ALPC-006
cable is supplied
with the ALP Auxiliary
Power Supply.
Drive #1
-V Auxiliary
Supply
220µ
J3
F
+V Auxiliary
Supply
127 to 373
VDC
Drive #2
-V Auxiliary
Supply
220µ
J3
F
+V Auxiliary
Supply
127 to 373
VDC
Installation
J3
0.5 Amp
AC
Fuses
0.5 Amp
Fuses
17

Hide quick links: