Installation Guide
3

Transport, unpacking and setting-up

3.1

Transporting the heat pump

Caution
Caution
When transporting indoors to the installation location it may be necessary to place the heat pump on its back. The time that the heat
pump is transported on its back should be as short as possible. After the heat pump has been lifted up again it must stand upright for at
least an hour before commissioning.
3.2

Unpacking

3.2.1
Unpack the heat pump
1. Check that there is no transport damage.
2. Remove the packaging.
3.2.2
Delivery check
1. Check that the delivery contains the following components:
Safety valve 9 bar ½"
Safety valve 1,5 bar ½" or 3 bar 1/2''
Outdoor sensor
Expansion and bleed tank or Expansion vessel with manometer
Rubber bellows for 22-28 mm hole
Flexible hose R20 L=550
Flexible hose R25 L=550
Filling device DN25
Filling device DN32
Dirt strainer with shut off valve DN20
Dirt strainer with shut off valve DN25
Manual holder
3.3

Setting-up the heat pump

10
Domestic heat pumps
During transportation or lifting of the entire heat pump, the front panel must always be installed as it locks
the other panels construction.
The heat pump must always be transported and stored in a dry area. Secure the heat pump so that it cannot
tip over during transportation.
VMGFQ102
4-10 kW
12 kW
1
1
1
1
1
1
1
1
5
5
2
-
-
2
1
1
-
-
1
-
-
1
1
1
16 kW
1
1
1
1
5
-
2
-
1
-
1
1
Danfoss Heating Solutions