Installation Guide
5.2.1
System solution 1
Description
In system solution 1 the heat pump can produce both heating and hot water with the compressor and the integrated immersion heater.
Production of heating and hot water cannot occur at the same time because the exchange valve for heating/hot water is positioned
after the immersion heater.
The integrated immersion heater carries out peak heating charging (antilegionella function) in those operating modes that permit auxili-
ary heat.
For system solution 1, select the factory setting in menu SERVICE\AUX. HEATER\EXTERNAL ADDITION:
▪ EXTERNAL AUX. HEATER = 0 (Off)
▪ REV.V. HOT WATER = INT
Example system solution 1
System solution for DHP-H, DHP-H Opti, DHP-H Opti Pro, DHP-C Opti, DHP-C Opti W/W, DHP-A, DHP-A Opti.
Danfoss Heating Solutions
Domestic heat pumps
1
Heat pump
10
Supply line
11
Return line
12
Cold water
13
Hot water
80
Shut-off valve
83
Non-return valve
85
Air bleeding valve
86
Safety valve expansion heating system
87
Safety valve cold water 9 bar
89
Vacuum valve
91
Dirt strainer with shut off valve
96
Flexible hose
113
Expansion heating system
126
Safety valve for temperature and pressure (only applies to certain models)
VMGFQ102