Connection outdoor unit to DHP-A
3
3
Outdoor unit
80
Shut-off valve
84
Manometer
85
Air bleeding valve
94
Filling device
96
Flexible hoses
100
Safety valve
Connection brine DHP-C Opti W/W
5.3.2
Drill holes for brine pipes
Caution
Caution
28
Domestic heat pumps
96
80
Ensure that the holes for the insert pipes are positioned so that there is room for the other installations.
The brine pipes shall have separate lead-ins. If the wall lead-ins are below the highest ground water level wa-
tertight lead-ins must be used.
VMGFQ102
85
100
84
112
C
94
121
B
A
112
Expansion vessel
121
Brine in
122
Brine out
A
Shut-off valve (part of 94)
B
Shut-off valve (part of 94)
C
Dirt strainer with shut off valve (part of 94)
D
Moved out sensor, brine out
73 71
85
122
D
71
Flow guard
73
2-way valve
85
Air bleeding valve