Installation Guide
Example system solution 3
System solution for DHP-L, DHP-L Opti.
5.2.4
Connect cold and hot water lines
1. Connect the cold water and hot water pipes with all the necessary components according to the connection diagram for the rele-
vant system.
5.2.5
Connect the heating system supply and return lines
For information on how flexible hoses should be installed, see Flexible hoses.
1. Connect the supply pipe with a flexible hose connection and with all the necessary components.
2. Connect the return pipe with a flexible hose connection and with all the necessary components including a filter.
3. Insulate the supply and return lines.
4. Connect the bleed valve to the outlet (22mm Cu) on the top of the heat pump.
5.3

Connection brine

26
Domestic heat pumps
1
10
11
12
13
18
36
51
72
77
80
83
86
87
89
91
96
113
117
118
126
VMGFQ102
Heat pump
Supply line
Return line
Cold water
Hot water
Hot water tank
Circulation pump
Supply line sensor, moved out from heat pump
Shunt valve
Reversing valve
Shut-off valve
Non-return valve
Safety valve expansion heating system
Safety valve cold water 9 bar
Vacuum valve
Dirt strainer with shut off valve
Flexible hose
Expansion heating system
External auxiliary heater
Safety valve 2,5 bar
Safety valve for temperature and pressure (only applies
to certain models)