Danfoss DHP-A Installation Manual page 14

Domestic heat pumps
Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

Installation Guide
Prepare the outdoor unit
While the outdoor unit remains on the pallet it should be prepared for placing on the stand.
Caution
1. Unscrew the three M6x20 screws (on the lower edge of the outdoor unit) so that 2-3 mm of the thread remains. Use a torx TX25
screwdriver, or equivalent.
2. Raise the outdoor unit.
3. Remove the side plates. They are held in place by clamps and so are removed by pulling outwards.
4. Remove all four screwed lifting eyes. Use a 13 mm wrench, or equivalent.
Assemble the outdoor unit on the stand
Caution
1. Lift the outdoor unit into the place on the stand.
2. Screw the outdoor unit onto the stand. Use 4 x M6x20 screws. It may be necessary to push and pull the stand slightly in order to get
the screw holes to align.
3. Reinstall the side panels.
Assemble the defrost sensor
Assemble the front cover
1. Hook the lower edge of the front cover onto at least one of the three screws in the bottom edge of the stand.
2. Secure the upper edge of the front panel temporarily in the centre hole. Use 1 x M6x15 torx TX25.
3. Align all the three screws in the lower edge.
4. Screw the three screws in the lower edge fully. Use a torx TX25 screwdriver, or equivalent.
5. Secure the front panel's upper edge with the 2 x remaining M6x15 torx TX25, see figure below.
14
Domestic heat pumps
Do not lift the outdoor unit by its side panels when it is to be raised or moved.
When filling the brine system the outdoor unit must be bled using the bleed screws on the connecting pipes
inside the side covers. We recommend that you return to this instruction after the brine system has been fil-
led.
1. Slide the mounting for the defroster sensor into the hole on the reverse of the outdoor unit
until the cover hooks into place on the edge.
2. Take out the defrosting sensor from the electrical connection box. Thread out the sensor
through a suitable lead-in.
3. Route the defroster sensor connection cable through the cable lead-in to the mounting.
4. Secure the defroster sensor at the bottom of the mounting using a cable tie.
VMGFQ102