If the sensor cable is connected through a pipe, the pipe must be sealed so that the sensor is not affected by
N
outgoing air.
1. Position the outdoor sensor on the north or north west side of the house.
2. Connect the sensor to the heat pump's control system.
6.5

Connect outdoor unit

Caution
The power cable may only be connected to the terminal block intended for this purpose. No other terminal
blocks may be used!
Outdoor unit
1
N/220
2
211
3
213
104
4
218
386
5
387
6
125
N/220
7
126
N/220
8
127
1. Route the power cable through the opening in the top panel of the heat pump to the terminal blocks.
2. Connect the power cable to the terminal block.
6.6

Connect temperature sensor hot water

Sensor for hot water and hot water peak from external water heater is connected in the following way to DHP-L.
54
55
Danfoss Heating Solutions
Domestic heat pumps
Heat pump
PE
220/N
211
213
283
104
218
386
387
125
311
312
325
326
1
Neutral
2
Fan high speed
3
Fan low speed
4
Motor protection fan
5
Defrost sensor
6
Accessories
7
Heating, drip tray
8
Heating cable
54
Hot water sensor
55
Hot water top sensor
VMGFQ102
35