Filling and bleeding the brine system

10.4.1
Introduction
Caution
Caution
Caution
Caution
N
N
52
Domestic heat pumps
Before filling the brine system, the electrical installation must be completed so that it is possible to operate
the brine pump.
Before filling the brine system for DHP-A the water heater MUST be filled.
Always check local rules and regulations before using anti-freeze.
For DHP-C Opti W/W: The pressure on the brine system must not exceed 3 bar and the difference pressure
must be at least 120 kPa.
Bleed the system thoroughly
Anti-freeze with corrosion protection additives must be used and mixed to achieve frost protection down to
-17 ±2°C for DHP-H, DHP-L and DHP-C Opti.
Use only of Danfoss recommended ethylene glycol as anti freeze for DHP-A mixed to achieve frost protection
down to -32±1°C.