Danfoss DHP-A Installation Manual page 47

Domestic heat pumps
Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

Installation Guide
Menu selection
Meaning
LOG TIME
Time interval between collection points of temperature history in minutes. The history
graphs always show the 60 last collection points, which means that the graphs can dis-
play history from 1 hour up to 60 hours ago.
(The function is not active if there is an active alarm).
BRINE TIME ON
The brine pump starts the set number of seconds before the compressor. Applies at start
of heat pump.
The brine pump stops the set number of seconds after the compressor. Applies at stop of
BRINE TIME OFF
heat pump.
SYSTEM
Menu selection
HEAT SOURCE
COOLING
POOL
SHUNT GROUP
BUFFER TANK (See separate instruction
for buffer tank)
ADDITION
Danfoss Heating Solutions
Domestic heat pumps
Meaning
GROUND OR ROCK
OUTSIDE AIR
(BRINE SOLUTION, DIRECT EVAP.)
PASSIVE COOLING
(
, PASSIVE, INTEGRATED IN HP)
ACTIVE COOLING
(
, PASSIVE/ACTIVE, ACTIVE)
ROOM SENSOR
(
, ON)
, ON
, ON
BUFFER TANK
SYSTEM SHUNT
2ND H.C SHUNT
OPTIMUM
(
, CIRC. PUMP, TWO WAY VALVE)
HGW
(
, ON)
FLOW SENSOR
(
, ON)
CURRENT LIMITER
(
, ON)
PHASE FAULT
(
, PHASE READING)
Factory setting
B/W
Permanently ON or ON/
model.
VMGFQ102
Factory setting
1M
(range: 1M / 60M)
30S
(range: 10S / 90S)
30S
(range: 10S / 60S)
depending on
47