Sub-Menu Manual Test - Danfoss DHP-A Installation Manual

Domestic heat pumps
Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

Installation Guide
9.4

Sub-menu MANUAL TEST

Menu selection
Meaning
0 = deactivate manual test
MANUAL TEST
1 = activate manual test
2 = activate manual test with option of navigating from the SERVICE menu to check that the tempera-
tures rise for example.
0 = stop heat pump
HEAT PUMP
1 = start heat pump
0 = stop the brine pump
BRINE PUMP
1 = start the brine pump. If the value for Optimum is set to On the value can be controlled between 30
– 100.
0 = stop the circulation pump
CIRC. PUMP
1 = start the circulation pump If the value for Optimum is set to On the value can be controlled be-
tween 30 – 100.
REV.V. HOT WATER 0 = heating mode for the exchange valve
1 = hot water mode for the exchange valve
- = closes shunt
SHUNT
0 = shunt unaffected
+ = opens shunt
Only at buffer tank
SYSTEM SHUNT
- = closes shunt
0 = shunt unaffected
+ = opens shunt
- = closes shunt
HGW-SHUNT
0 = shunt unaffected+ = opens shunt
0 = stop aux. heater step 1
AUX. HEAT 1
1 = start aux. heater step 1
0 = stop aux. heater step 2
AUX. HEAT 2
1 = start aux. heater step 2
0 = stop aux. heater step 3
AUX. HEAT 3
1 = start aux. heater step 3
EXT.AUX.HEATER
0 = stop external auxiliary heater
1 = start external auxiliary heater
0 = stop circulation pump
EXT.CIRC. PUMP
1 = start circulation pump
- = opens flow from defrosting tank
SHUNT DEFR
0 = shunt unaffected
+ = closes flow from defrosting tank
FAN L
0 = stop fan
1 = start fan at low speed
0 = stop fan
FAN H
1 = start fan at high speed
0 = 0V on plinth 283
EXT. AUX. HEATER
1 = control voltage 230V on plinth 283
0 = stop signal on output External alarm
ALARM
1 = start signal on output External alarm
SHUNT COOLING
- = closes shunt
0 = shunt unaffected
+ = opens shunt
- = closes shunt
SHUNT GROUP
0 = shunt unaffected
+ = opens shunt
Danfoss Heating Solutions
Domestic heat pumps
The heat pump cannot be started in the event of an active alarm.