5.2.2
System solution 2
Description
In system solution 2, the heat pump can produce both heat and hot water and an external auxiliary heater (oil boiler, electric boiler,
district heating or similar) supports heat production but not hot water production. The exchange valve for heating/hot water is located
ahead of the external auxiliary heater, which allows the production of heating and hot water at the same time.
The integrated immersion heater can be used for heating and hot water production as well as for antilegionella. The values of the inte-
grals, A2 and A3 are used to select if the external auxiliary heater is to step in before or after the integrated immersion heater.
The heat pump control computer also controls an additional shunt located after the external addition.
For system solution 2, select in menu SERVICE\AUX. HEATER\EXTERNAL ADDITION:
▪ EXT.AUX.HEATER = ON
▪ REV.V. HOT WATER = INT
Example system solution 2
System solution for DHP-H, DHP-H Opti, DHP-H Opti Pro, DHP-C Opti, DHP-C Opti W/W, DHP-A, DHP-A Opti.
Danfoss Heating Solutions
Domestic heat pumps
1
Heat pump
10
Supply line
11
Return line
12
Cold water
13
Hot water
36
Circulation pump
51
Supply line sensor, moved out from heat pump
72
Shunt valve
80
Shut-off valve
83
Non-return valve
85
Air bleeding valve
86
Safety valve expansion heating system
87
Safety valve cold water 9 bar
89
Vacuum valve
91
Dirt strainer with shut off valve
96
Flexible hose
113
Expansion heating system
117
External auxiliary heater
126
Safety valve for temperature and pressure (only applies to certain models)
VMGFQ102
23