3. Setting
3.7.
Setting Menu
4: LCD Settings (Setting Model Display, Version Display, Backlight, and
This section is for confirming the model, option code and the product version, and also set the backlight and the display
update time.
In the operation mode, press
becomes available.
Setting menu
DISPLAY
SET
Model + option code
DISPLAY
SET
②Version display
DISPLAY
SET
Backlight brightness
DISPLAY
SET
Backlight auto off
DISPLAY
SET
⑤Display update time
SET
Setting Menu

Display Update Time)

+
SET
RESET
Set the setting menu number to "4".
(as shown in the right figure)
The model can be confirmed. (This is only display, and settings cannot be changed.)
(1)
Middle Line
(2)
Lower Line
Option code
The product version can be checked.
(The product version is displayed, but cannot be changed.)
The backlight brightness can be adjusted.
1
2
Dark
The backlight can be set to continuous on (HoLd)
or auto off (Auto).
Auto
(Auto off)
(Continuous on)
<When auto off (Auto) is selected>
No button operation for 5 minutes → the backlight turns off
Button operation during off (Note) → the backlight turns on
The display update time for the measured value can be change.
If the display switches too quickly for you to read the displayed
value, set it to 1.0 second.
(Normally, leave this setting to 0.5 second.)
0.5second
According to the setting flow (page 16 to 21), save the changed
contents, or continue to the other setting menu.
simultaneously for 2 seconds or more, and the following operation
Model
ME96SSRA-MB
Blank
ME-4210-SS96
ME-0040C-SS96
ME-0052-SS96
ME-0000MT-SS96
ME-0000BU-SS96
3
4
5
Bright
HoLd
Note: When the backlight is off, pressing any
button once does not switch the display but only
turns on the backlight.
Pressing any button again switches the display.
for 5 minutes
1second
33
*1 If "E90xx" appears,
MODBUS®TCP
communication
error will be occurred.