  • Page 1 Energy Measuring Unit Simple & Easier Simple & Easier Providing Energy Visualization Providing Energy Visualization...
  • Page 2 Simple & Easier Providing Energy Visualization. Introducing the EcoMonitorLight, an energy measuring unit with an integrated display that provides  easy energy visualization in order to provide ways to save  energy and to comply with the Energy  Saving Act in response to the need for a simple manner to figure out energy consumption. EMU4-BD1-MB The EcoMonitorLight is suitable if you are thinking   Just want to measure energy Considering system expansion in the future. in a simple low-cost manner. But is this product okay for now? The integrated display allows you to perform the main unit settings First, start from checking conditions in locations you are and check measured values quickly.
  • Page 3 C o n t e n t s   1. Features   2. Product Lineup EMU4-HD1-MB   3. Examples of EcoMonitorLight Applications   4. Specifications   5. External View   6. Names and Functions of Each Part   7. Connection Configurations     /Wiring Precautions   about the following.     8. Communication Unit Wiring and     Setting Procedures      9. Device Installation Procedures Want to easily manage measurement 10. Energy measuring devices data from specific locations. 11. Model Name/Specifications 12. Safety Precautions We can provide you with free software for managing data using a personal computer.
  • Page 4 Display device (GOT)  ③     *1: Data Acquisition Software (EMU4-SW1) can be downloaded for free from the Mitsubishi Electric website.    *2: A sample GOT screen can be downloaded for free from the Mitsubishi Electric website. (GT14**-Q, GT1030) Host System MELSEC MELSEC...
  • Page 5 Expansion by use of Logging and Communication Units ■Logging Unit  Use of a logging unit allows you to output various energy (such as current, voltage and power) data measured using the energy measuring unit in CSV file format on an SD memory card for easy data management.   ■Communication Unit (CC-Link Communication Unit)  A communication unit can be connected to the system using CC-Link communication.
  • Page 6: Measurement Functions

    1. Features Measurement Functions ■High-Precision Measurement ■Operating Time Measurement The continuous measurement of energy at sampling The current measurement time can be calculated in cycles of approximately 250 μs allows for measuring seconds and the equipment operating time can be even short-cycle loads such as that for spot or solder displayed in hours (h) in order to utilize the data in welding.
  • Page 7 *Please contact your nearest Mitsubishi Electric branch office or representative for information regarding the standards compliance status of each model. Correspondence from production in February 2014. (Except for some models)...
  • Page 8: Product Lineup

    2. Product Lineup Energy Measuring Unit *Photos are full-scale. The lineup consists of two types of measuring unit to  make it simpler to easily visualize energy consumption. EMU4-HD1-MB EMU4-BD1-MB High Performance Model Standard Model EMU4-HD1-MB EMU4-BD1-MB For customers who need more advanced  For customers who want to start measuring  energy in a simple and low-cost manner! functions than those of the standard model such  as three-phase 4-wire measurement,  pulse count and contact input! ①Same basic functions as the Standard Model. ①Equipped with basic energy measurement functions such as for current, voltage, power and electric energy. ②Three-phase 3-wire 440V direct voltage input is available.
  • Page 10 3.Examples of EcoMonitorLight Applications 3.Examples of EcoMonitorLight Applications Configuration Example of Measuring Devices ■Basic Installation ○You can use a general-purpose cable between the measuring unit and dedicated split current Control Power Supply sensor. (Except for (EMU2-CT5 ( -4W) ) AC100V〜240V(50/60 Hz) ○Always use in combination with a dedicated Voltage Input split current sensor. ○Give consideration to the rated current of the installation location for the dedicated split current sensor and select a model accordingly.
  • Page 11 You can manage data from multiple Examples of CSV data screens logging units on a single SD memory card. You can download the GX LogViewer free of charge from the Mitsubishi Electric website. “GX LogViewer” corresponds also after version 1.30 G. Features of Logging Unit  (1) Easy Data Management with SD Memory Card   ●You can output various types of measurement data (such as voltage, current and power) of the EcoMonitorLight stored in the logging unit to an SD memory  ...
  • Page 12 Energy management software (EMU4-SW1) performs data acquisition from energy measuring units equipped with a MODBUS RTU communication interface. ® * Data Acquisition Software (EMU4-SW1) carries out free download, and gets from the "design supportive tool data" of the Mitsubishi Electric site (http://www.MitsubishiElectric.co.jp/haisei/lvs/) energy-saving supporting aircraft machine menu. Features of the Data Acquisition Software (1) Capable of collecting a maximum of 124 items of measurement data from ...
  • Page 13 Examples of Data Acquisition Software (EMU4-SW1) Display Screens PC with Data Acquisition (1) Current Values Display software installed* Converter Main Screen Selected measurement items are displayed in real time Current values are updated every one second (2) Measurement data is logged in the specified cycle. (4) Communications are used for settings Communication Settings Data Storage Terminal Registration Data is logged in CSV format every one minute or one hour. (3)...
  • Page 14 You can view current values of various energy information such as power, current and voltage, and also display graphs of current and electric energy* You can download the sample GOT screen free of charge from the Mitsubishi Electric FA website.
  • Page 15 Connection to PLC System ■Energy Management with PLC  For custormers who want to capture energy information in the PLC system, and manage    production information and other types of data in an integrated manner. Available uses include preventive equipment maintenance by using energy amount measurement and real-time measurement of each piece of production equipment, and linking of quality control indicators with production information.
  • Page 16: Specifications

    4.Specifications Energy Measuring Unit Energy Measuring Unit General Specifications Item Specification Model EMU4-HD1-MB EMU4-BD1-MB Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire Single-phase 2-wire, single-phase 3-wire Phase wire system and three-phase 3-wire (Settings switching) and three-phase 4-wire (Settings switching) Single-phase 2-wire 110V, 220V, 440V AC Common 110V, 220V AC Common Single-phase 3-wire Voltage circuit...
  • Page 17 Item Specification Model EMU4-HD1-MB EMU4-BD1-MB EMC:EN-61326-1:2006 Compatible standards Safety:EN-61010-1:2010 Operating temperature range ー5℃〜+55℃ (average daily temperature of 35°C or less) Operating humidity range 30%〜85% (no condensation) Operating environment Storage temperature range ー10℃〜+60℃ Altitude 2,000 m or less Applies to all terminals ( excluding communication and frame GND terminals) , between external boards: 2,000V AC for 1 min. Applies to all current/voltage inputs, between auxiliary powers: 2,000V AC for 1 min.
  • Page 18 6.4V DC (Power supplied from energy measuring unit) Power interruption backup Total power interruption backup time of the lithium battery (EMU4-BT) is one year (avg. daily temp. of 35°C or less); Mitsubishi Electric recommends replacing the battery every three years. Saved in FRAM (non-volatile memory) Set values *Data is not deleted if there is a power outage.
  • Page 19 CC-Link Communication Unit CC-Link Communication Unit Basic Specifications Item Specification Model EMU4-CM-C Auxiliary power rating 6.4V DC (6.4V DC Power supplied from energy measurement unit) Compatible model Energy measuring unit (EcoMonitorLight)  EMU4-HD1-MB、 EMU4-BD1-MB Compatible standard EMC EN-61326-1:2006 Operating temperature range ー5℃〜+55℃ (daily average temperature of 35°C or less) Operating humidity range 30%〜85%RH (no condensation) Operating...
  • Page 20 4.Specifications Optional Parts Optional Parts Split-type Current Sensor Item Specifications Model  EMU-CT50 EMU-CT100 EMU-CT250 EMU-CT400 EMU-CT600 Rated primary current 50A AC 100A AC 250A AC 400A AC 600A AC Rated secondary current 16.66mA 33.33mA 66.66mA 66.66mA 66.66mA Rated load 0.1VA Maximum use voltage 460V AC Ratio error ±1% (5 to 100% of rating, RL ≤...
  • Page 21 Report output Output types Monthly, daily and detailed (1-min intervals) * Data Acquisition Software (EMU4-SW1) carries out gratis download, and gets from the "design supportive tool data" of the Mitsubishi Electric web site          (http://www.MitsubishiElectric.co.jp/haisei/lvs/) energy-saving supporting aircraft machine menu.
  • Page 22: External View

    5. External View Energy Measuring Unit Units (mm) Units (mm) 〔High Performance Model〕 EMU4-HD1-MB 〔Standard Model〕 EMU4-BD1-MB Panel Mounting Attachment (EMU4-PAT) when Installed Panel Mounting Attachment (EMU4-PAT) Logging/Communication Unit Logging Unit Logging Unit CC-Link Communication Unit CC-Link Communication Unit (EMU4-LM) (EMU4-LM) (EMU4-CM-C) (EMU4-CM-C) LOG. L RUN SD CARD SD C.
  • Page 23 Optional Parts Units (mm) Units (mm) Split-type Current Sensor Split-type Current Sensor EMU-CT50、 EMU-CT100、 EMU-CT250 Split-type Current Sensor EMU-CT50、 EMU-CT100、 EMU-CT250 Split-type Current Sensor EMU-CT400、 EMU-CT600 Split-type Current Sensor EMU-CT400、 EMU-CT600 Terminal protection cover Core cover Secondary terminal screw M4 screw Iron core divided face Secondary screw M4 screw Secondary short circuit switch Stopper Movable core Movable core fixing tab Terminal cover Model...
  • Page 24: Names And Functions Of Each Part

    6.Names and Functions of Each Part 6.Names and Functions of Each Part Energy Measuring Unit [High Performance Model] EMU4-HD1-MB Codes and Functions of Terminal Block Terminal Code Function Description P1/P1,P2/P0 Input voltage Connect the voltage input wire Voltage Input Termina Frame GND Terminal for the measuring circuit. P3/P3,NC/F2 Auxiliary Power Terminal Frame GND (FG) Connect to ground (D type ground). MA,MB Auxiliary power Connect the auxiliary power supply.
  • Page 25 Logging/Communication Unit Logging Unit EMU4-LM Names and Functions of Each Part Name Function LOG.LED Front View Left-side View Backside View 1) Displays logging operation status.  Lit up: Logging is being performed.  Not lit up: Logging operation is stopped.  Slow flashing* (5 sec.): Changing of logging conditions  settings has been completed.  Fast flashing* (30 sec.): Changing of logging conditions  settings has failed.
  • Page 26: Connection Configurations

    7.Configurations/Wiring Precautions 7.Configurations/Wiring Precautions Connection Configurations For EMU4-HD1-MB 1P2W (For high-voltage circuit) 1P2W (For high-voltage circuit) 1P3W/3P3W (For low-voltage circuit) 1P3W/3P3W (For low-voltage circuit) Power source side Power source side EMU-CT*** Model Current Transformer Split Current Sensor (Secondary Current 5A Part) (50/100/250/400/600) 5A Current Sensor External Outputs EMU2-CT5 External Outputs External Inputs External Inputs 5A Current Sensor Cable Load Side Load Side EMU2-CB-Q5B...
  • Page 27: Wiring Precautions

    The value for the primary voltage of the transformer can be specified up to 6,600 V when using a transformer for circuits. ® Mitsubishi Electric recommends having an extra length of approximately 20 cm for MODBUS communication wiring. ●...
  • Page 28 8.Communication Unit Wiring and Setting Procedure 8.Communication Unit Wiring and Setting Procedure CC-Link Communication Unit Wiring Procedures ①Rotate the levers on both ends of the CC-Link communication connector and remove When installed in the middle it from this unit. of a transmission path: ②Loosen the cable-clamping screw of the CC-Link communication connector. Use a thin flat-head screwdriver (tip thickness: 0.6mm; total length: 3.5 mm) DB DA ③Insert the signal wire according to the indications on the side of the CC-Link communication connector.
  • Page 30 9.Device Installation Procedures Energy Measuring Unit IEC Rail Installation (Surface Installation) ●Applicable IEC Rail ●Installation ●Removal   (35mm) ①Pull the IEC rail stopper  of the main unit downward. 仮写真 ②Hooks IEC Rail ②Pull up 7.3 or more ①Press against the main unit ③Push using your hand so that it ④Push the IED rail does not fall, and pull the  stopper upward.
  • Page 31: Optional Units

    Optional Units Common for Logging Unit and CC-Link Communication Unit Connect optional units to the energy measuring unit. ①Peel off the blank label affixed to the left side ②Insert the connector of the optional unit into the connector  of the main unit of the energy measuring unit.  of the energy measuring unit to closely attach the unit. Blank Label ③Slide the coupling tab (green) on top of the optional  unit to lock the optional unit.
  • Page 32 10. Energy measuring devices EcoMonitor Series  EcoMonitor Series  EcoMonitorPro EcoMonitorLight Simple, easy measuring with low cost! Measure multiple circuits according to various applications! 【Features】 【Features】 ・Low-cost series lineup ・You can select a model corresponding to the amount of circuits ・Standard-equipped with MODBUS RTU communication (RS485) from one to seven.
  • Page 33 Specifications of Measurement Terminals Specifications of Measurement Terminals Model Name EcoMonitorLight EcoMonitorPro External appearance External dimensions (mm) W75×H90×D75 W186×H90×D97(7-Circuit Model) Installation method IEC rail or board-surface installation IEC rail installation Models with single-phase 2-wire, single-phase 3-wire No. of measurement circuits and three-phase 3-wire: 1, 3, 5, and 7 circuits 1 circuits Three-phase 4-wire model: 2 and 4 circuits Auxiliary power rating...
  • Page 34 11.Model Name/Specifications ■EcoMonitorLight Measuring Unit ■EcoMonitorLight Measuring Unit Model Name and Specifications of EcoMonitorLight Measuring Unit Product Name    Unit Specifications Measures various energy items (such as current, voltage, power, power use and harmonics). Energy Measuring Unit EMU4-HD1-MB Standard-equipped with MODBUS RTU (RS485), Pulse and Contact input and output, ® : High Performance Model Compatible with three-phase 4-wire.
  • Page 36: Safety Precautions

    12.Safety Precautions Precautions for Operating Environment and Conditions for Use ●This unit is premised on being used in a pollution degree 2* environment. Protect this unit from pollution on the side where another device is to be assembled when using in an environment with a different pollution degree. ●The measurement category of the measuring circuit in this unit is CAT II* and the energization voltage category of the auxiliary power circuit (MA and MB) is also CAT II.
  • Page 37 <Connection with Current Sensor> ●Always be sure to use this unit in combination with a dedicated current sensor (EMU-CT50, EMU-CT100, EMU-CT250, EMU-CT400, EMU-CT600, EMU2-CT5, or EMU2-CT5-4W). This unit cannot be directly connected to the secondary side (5 A) of a current transformer. Do not use a current sensor input that exceeds the corresponding rating of this unit.
  • Page 38 13. Memo Memo...
  • Page 39 Memo...
  • Page 40 Sao Paulo, SP, CEP:01311-200, Brazil Chile Rhona S.A. Agua Santa 4211 P.O. Box 30-D Vina del Mar, Chile + 56-32-2-320-600 No. 1386 Hongqiao Road, Mitsubishi Electric Automation Center China Mitsubishi Electric Automation (CHINA) Ltd. + 86-21-2322-3030 Shanghai China, 200336 10/F., Manulife Tower, 169 Electric Road, North Point, China Mitsubishi Electric Automation (HongKong) Ltd.

This manual is also suitable for:

Ecomonitorlight emu4-hd1-mb

Table of Contents