Mitsubishi Electric ME96SSRA-MB User Manual page 14

Electronic multi-measuring instrument
Hide thumbs Also See for ME96SSRA-MB:
Table of Contents

Advertisement

1. Display and Button Functions of Each Parts
Functions of operation buttons
The operation buttons have various functions
According to how they are pressed down.
Meaning of code:
(press),□(press on over 1 second),◎(press on over 2 seconds),―― (press simultaneously)
Operation
Mode
SET
Note: While the back light is off, if the operation button is pressed, the back light is always lit. If the operation button is
pressed once again, the function in the above table appears.
If the function of "maximum value and minimum value reset" and "Wh, varh, VAh zero reset" are
done, data will be lost. If this data is needed, please record the data before the reset operation.
CAUTION
If the function of "meter restart" is done, the entire measurement(measurement display, alarm,
analog output, pulse) stops.
Button
RESET MAX/MIN PHASE DISPLAY
SET
RESET MAX/MIN PHASE
Set button
Reset button
+/-button
Maximum/Minimum button
Display changes.
Display changes.(reverse direction)
Phase changes.
Mode changes to the max./min. display and the instantaneous display
The item expressed with the bar graph is changed.
Harmonics number changes when harmonics displayed.
Displays change cyclically. (Refer to page 65)
Phases change cyclically. (Refer to page 65)
Change the unit of Wh, varh and VAh, etc.
Maximum values and minimum values on
the display are reset to the present value.
All of the Maximum values and minimum
values are reset to the present value.
Wh, varh, VAh are zero reset. (All of the counting values are zero reset.)
Periodic active energy is zero reset. (Only effective in Periodic active
energy display)
Adjusting rolling demand time(Only effective in rolling demand display)
Resetting the peak value of rolling demand (Only effective in rolling
demand display)
The operation time is zero reset (Screen operation time only)
An alarm condition is canceled.
(Screen element is canceled)
All alarm conditions are canceled.
(Element is canceled for all screens)
Stopping backlight flickering alarm.
flicker)
The latching data of digital input on the display is canceled.
(Available only for contact point input screen)
The display of Setting mode appears.
The display of Set value confirmation mode appears.
The display of
password protection
The setting items are saved, and setting item is changed to next item.
Back to the previous item.
The values of setting are changed.
(If it presses for 1 sec or more fast forward or fast return.)
Back to the setting display.
Save the settings(Only effective in End display)
Cancel the settings(Only effective in CANCEL display)
Meter
restart(Only effective in CANCEL display)
Returns set contents to the default settings
effective in CANCEL display) (Refer to page 52)
13
DISPLAY
Phase button
Display button
Function
(Refer to page 68)
Only available for
maximum/minimum
value display
Available only when
manual cancelation is
set
(Only effective in
setting backlight
mode appears.
(the default values,
Only

Advertisement

Table of Contents
loading

Table of Contents