Setting Table (Factory Settings And Customer Setting Note) - Mitsubishi Electric ME96SSRA-MB User Manual

Electronic multi-measuring instrument
Hide thumbs Also See for ME96SSRA-MB:
Table of Contents

Advertisement

Specifications

7. Setting Table (Factory Settings and Customer Setting Note)

Setting menu No.
1.1
Phase wire system
1.2
Display pattern
1.2.1
Pattern P00
1.3
VT/direct selection
1.3.1
Direct voltage
1.3.2
VT secondary voltage
1
1.3.3
VT primary voltage
1.4
CT secondary current
1.4.1
CT primary current
1.5
Frequency
1.6
Time constant for rolling demand (Interval time constant)
1.6.1
Subinterval time constant
1.7
Time constant for current demand
2.1
Communication setting selection
2.2
MODBUS
2.2.1
MODBUS
2.2.2
MODBUS
2.2.3
MODBUS
2.3
CC-Link station number
2.3.1
CC-Link baud rate
2
2.3.2
CC-Link version
2.3.3
Communication reset
2.4
MODBUS
MODBUS
MODBUS
MODBUS
Communication reset
3.1
Current maximum scale
3.1.1
Special current maximum scale
3.2
Voltage maximum scale
3.3
Power maximum scale
3
3.3.1
Single / Double deflection
3.4
Reactive power maximum scale
3.5
Power factor scale
3.6
Expanded counting
3.7
Harmonics display
4.1
Model name + option code
4.2
Version display
4
4.3
Back light brightness
4.4
Back light auto off
4.5
Display update time
5.1
Alarm item 1
5.1.1
Alarm value 1
5.2
Alarm item 2
5.2.1
Alarm value 2
5.3
Alarm item 3
5.3.1
Alarm value 3
5.4
Alarm item 4
5.4.1
Alarm value 4
5.5
Alarm delay time
5.6
Alarm cancel method
5
5.7
Back light flickers during alarms
5.8
Motor start-up current masking
5.8.1
Motor start-up current threshold
5.8.2
Motor start-up current delay time
5.9
Pulse / Alarm output 1 (With ME-4210-SS96)
5.9.1
Pulse output 1: output item
5.9.2
Pulse output 1: pulse unit
5.10
Pulse / Alarm output 2 (With ME-4210-SS96)
5.10.1
Pulse output 2: output item
5.10.2
Pulse output 2: pulse unit
5.11
Pulse width
Setting items
®
RTU address
®
RTU baud rate
®
RTU parity
®
RTU stop bit
®
TCP IP address
®
TCP Subnet mask
®
TCP Default gateway existence
®
TCP Default gateway
Initial content
3P4(3-phase 4-wire)
P04
no(No VT)
220/380V
5A
5A
50Hz
15min
1min
0s
CC or Mb.tCP
1
19.2kbps
EVEn(even)
1
1
156kbps
1.10
oFF
192.168.3.10
255.255.255.0
oFF(No existence)
127.0.0.1
oFF
5A(CT primary
current)
300V(±0 STEP)
4000W(±0 STEP)
Single deflection
4000var(±0 STEP)
0.5(-0.5 to 1 to 0.5)
Combination I
oFF
(Model name)
(Version)
3
Auto(Auto off)
0.5s
non
non
non
non
oFF
PULSE(Pulse output)
Wh
0.001kWh/pulse
AL (Alarm output)
0.125s
104
Memo

Advertisement

Table of Contents
loading