Setting Table (Factory Settings And Customer Setting Note) - Mitsubishi Electric ME96SSH-MB User Manual

Multi-measuring instrument
Hide thumbs Also See for ME96SSH-MB:
Table of Contents

Advertisement

Specifications

5. Setting Table (Factory Settings and Customer Setting Note)

Setting menu No.
1.1
Phase wire system
1.2
Display pattern
1.2.1
Pattern P00
1.3
VT/direct selection
1.3.1
Direct voltage
1.3.2
VT secondary voltage
1
1.3.3
VT primary voltage
1.4
CT secondary current
1.4.1
CT primary current
1.5
Frequency
1.6
Time constant for rolling demand (Interval time constant)
1.6.1
Subinterval time constant
1.7
Time constant for current demand
2.1
Communication method selection (With ME-0040C-SS96)
2.2
MODBUS
2.2.1
MODBUS
2.2.2
MODBUS
2
2.2.3
MODBUS
2.3
CC-Link station number
2.3.1
CC-Link baud rate
2.3.2
CC-Link version
2.4
Communication reset
3.1
Current maximum scale
3.1.1
Special current maximum scale
3.2
Voltage maximum scale
3.3
Power maximum scale
3
3.3.1
Single / Double deflection
3.4
Reactive power maximum scale
3.5
Power factor scale
3.6
Expanded counting
3.7
Harmonics display
4.1
Model name + option code
4.2
Version display
4
4.3
Back light brightness
4.4
Back light auto off
4.5
Display update time
5.1
Alarm item 1
5.1.1
Alarm value 1
5.2
Alarm item 2
5.2.1
Alarm value 2
5.3
Alarm item 3
5.3.1
Alarm value 3
5.4
Alarm item 4
5.4.1
Alarm value 4
5.5
Alarm delay time
5.6
Alarm cancel method
5
5.7
Back light flickers during alarms
5.8
Motor start-up current masking
5.8.1
Motor start-up current threshold
5.8.2
Motor start-up current delay time
5.9
Pulse / Alarm output 1 (With ME-4210-SS96)
5.9.1
Pulse output 1: output item
5.9.2
Pulse output 1: pulse unit
5.10
Pulse / Alarm output 2 (With ME-4210-SS96)
5.10.1
Pulse output 2: output item
5.10.2
Pulse output 2: pulse unit
5.11
Pulse width
6.1
Analog output CH1: output item
6.1.1
Detailed setting (1)
6.1.2
Detailed setting (2)
6.2
Analog output CH2: output item
6.2.1
Detailed setting (1)
6.2.2
Detailed setting (2)
6
6.3
Analog output CH3: output item
6.3.1
Detailed setting (1)
6.3.2
Detailed setting (2)
6.4
Analog output CH4: output item
6.4.1
Detailed setting (1)
6.4.2
Detailed setting (2)
6.5
Analog output limit
7.1
Periodic Active energy display
7.1.1
Control setting for switching time segments of periodic active energy
7.2
Rolling demand display
7
7.2.1
Rolling demand time setting
7.3
Digital input/output status display
7.3.1
Digital input reset method
8.1
Operating time display
Target for counting Operation time setting
8.1.1
8
8.1.2
Operating time threshold
8.2
Switch element information
8.3
Set IEC mode
Setting items
®
RTU address
®
RTU baud rate
®
RTU parity
®
RTU stop bit
Initial content
3P4(3-phase 4-wire)
P04
no(No VT)
220/380V
5A
5A
50Hz
15min
1min
0s
CC(CC-Link)
1
19.2kbps
EVEn(even)
1
1
156kbps
1.10
oFF
5A(CT primary current)
300V(±0 STEP)
4000W(±0 STEP)
Single deflection
4000var(±0 STEP)
0.5(-0.5 to 1 to 0.5)
Combination I
oFF
(Model name)
(Version)
3
Auto(Auto off)
0.5s
non
non
non
non
oFF
PULSE(Pulse output)
Wh
0.001kWh/pulse
AL (Alarm output)
0.125s
A
AVG
5A(CT primary current)
V
(L-N)
AVG
300V(±0 STEP)
ΣW
4000W(±0 STEP)
Single deflection
ΣPF
0.5(-0.5 to 1 to 0.5)
oFF
oFF(Not displayed)
non(Not switched)
oFF(Not displayed)
oFF(Manual)
oFF(Not displayed)
Auto(Auto off)
oFF
AUX(Auxiliary power)
123
oFF(Normal mode)
- 83 -